| 2796 Culver Avenue, Dayton, OH 45429 | Phone: 937-294-1041 E-mail: a.nabinger@motortech.com | ||
DC Gearmotor Data: EMR 171A100/116Basic DC Gearmotor Data -Standard Part Numbers 1. This rating is for gearbox only. To determine output of any motor gearbox combination, multiply motor torque by the torque multiplier for that ratio. Do not use the .250 dia. shaft for continuous duty above 700 oz. in. 2. Torque multiplier ratio is the gear ratio multiplied by its efficiency. ** Consult factory when exceeding 1250 oz. in. t. For applications below 200 oz. in., continuous duty, lengths La and Lb can be reduced by .210 in. Consult factory. BASIC EMR ARMATURE DATA 3 3. For complete EMR motor data and tolerances see Bulletin 170A100. HOW TO SELECT A UNIT The complete part number must include a standard EMR gearmotor part number (above) plus an applicable EMR armature dash number from the basic motor data chart (above). Use the following trial and error technique to start: 1. Assume motor speed of 5,000 RPM and divide it by the required output ORDERING Order by standard part number (example: 171A106-9), making sure to include the armature dash number. Note any modifications as exceptions to the standard.
|
e-mail website concerns to: webmaster@motortech.com Phone: 937-294-1041 |